DS-11 Series Spectrophotometer

Award Winning Performance
DeNovix takes spectrophotometry to a whole new level of performance with the DS-11 Series. This easy-to-use, compact instrument delivers full spectrum UV-Vis analysis and fluorescence capability making it ideal for rapid nucleic acid and protein quantification. Our customers agree and have made the DeNovix DS-11 Series the twice winner of the Reviewers’ Choice Product of the Year and the first life science instrument to be awarded the Platinum Seal of Quality by SelectScience based on scientist reviews for outstanding ease-of-use, performance, service and technical support.
Best in Class 1 uL Sensitivity and Highest Absorbance Capability
DS-11 Series Spectrophotometers set the industry standard for the lower detection limits of 0.5 -1.0 uL UV-Vis sample analysis. Detect to 0.75 ng/uL dsDNA, 0.60 ng/uL RNA or 0.04 mg/mL BSA. The DS-11 can measure samples with absorbance values as high as 750 absorbance units (at a 1 cm equivalent path length). This translates into 1125 mg/ml of BSA protein or 37500 ng/uL of dsDNA. This ultra high absorbance capability is achieved by using a remarkably small pathlength enabled by our SmartPath™ technology.
Easy to Learn. Fast to Use.
The DS-11 Series instruments feature the most powerful and intuitive software of its type. EasyApps™ software is designed by life scientists and combines with an intuitive touchscreen interface to ensure error-free operation and sample to data in under 3 seconds. Every instrument is ready to go right out of the box – no PC set-up or software installation required.
INTEGRATED ABSORBANCE AND FLUORESCENCE FOR UNMATCHED FLEXIBILITY
The Only All-In-One Microvolume and Cuvette Absorbance with Fluorescence Design
With the DS-11 Series you can equip your lab for today’s quantification requirements and for future assay challenges. Combine the ease of use, wide dynamic range and contamination information of UV-Vis with the enhanced sensitivity and specific quantification of fluorescence for total sample quality control.
Absorbance and Fluorescence quantification are unique but complementary methods for assessing concentration and quality of biological samples. The multi-award winning DS-11 Series of 1 µL Spectrophotometers and Fluorometers provides the most sensitive and widest dynamic range for UV-Vis absorbance and fluorescence capability in one combined instrument.
Software Features:
Specifications:
FX Module: Upgrade to Fluorescence
Instantly add the power of fluorescence detection to any DeNovix DS-11, DS-11+ or DS-C Spectrophotometer. The FX Module uses the same fluorescence detection as the DS-11 FX, DS-11 FX+ and QFX. Simply plug in this USB powered accessory and DeNovix fluorometric EasyApps are immediately enabled. With four user-selectable LEDs, the easy-to-use apps are compatible with a wide range of commercially available assays including those designed for Thermo Fisher’s Qubit™ fluorometer and Promega’s Quantus™ fluorometer platforms.
Absorbance and Fluorescence Quantification Infographic
Absorbance and Fluorescence quantification are unique but complementary methods for assessing concentration and quality of biological samples. The multi-award winning DS-11 Series of 1 µL Spectrophotometers and Fluorometers provides the most sensitive and widest dynamic range for UV-Vis absorbance and fluorescence capability in one combined instrument.
Selecting the appropriate quantification methods for biological samples is an important consideration in any quality control process. Download our infographic featuring comparisons of the key features of absorbance and fluorescence quantification and information on when each method should be applied or the results combined.
Resources:
Brochure:
User Guide:
Technical Notes:
Performance Data:
- DeNovix DS-11 Series vs. Thermo Fisher NanoDrop™ One Spectrophotometer (TN 166)
- DeNovix DS-11 Series vs. Thermo Fisher Qubit™ Fluorometer (TN 172)
- DeNovix SmartQC™ Contamination Alerts vs. Thermo Fisher Nanodrop™ Acclaro™ Technology (TN 178)
- DeNovix DS-11 Spectrophotometer Advantages vs. Thermo Fisher NanoDrop™ Spectrophotometer 2000 (TN 125)
- Microvolume Nucleic Acid Performance Data (TN 105)
- DS-11+ vs. Agilent 8453 Performance Data (TN 136)
- Microvolume Protein Performance Data (TN 107)
- Microvolume Protein Colorimetrics Assay Data (TN 108)
- Methods of Protein Quantification (TN 176)
- Microvolume Mode Carryover Studies (TN 113)
- Microvolume Alexa Fluor 555 Performance Data (TN 115)
- Peptide App Performance Data (TN 138)
- OD600 Measurements (TN 168)
SmartPath Technology:
- SmartPath™ Technology Explained (TN 126)
- SmartPath™ Technology and High Absorbance (TN 120)
- SmartPath™ Technology with Bridge Testing™ Verification Ensures Measurement Accuracy (TN 135)
Fluorescence Performance Data:
- DeNovix RNA Assay Performance Data (TN 200)
- Broad Range dsDNA Assay Performance Data (TN 157)
- High Sensitivity dsDNA Assay Performance Data (TN 158)
- Ultra High Sensitivity dsDNA Assay Performance Data (TN 159)
- Fluorescence Measurements Best Practices (TN 154)
- Absorbance and Fluorescence Quantification (TN 156)
- DeNovix dsDNA Fluorescence Assay Ranges (TN 162)
- Thermo Fisher Qubit™ RNA Assay Performance Data (TN 169)
- Thermo Fisher Qubit™ ssDNA Assay Performance Data (TN 171)
- GFP Quantification Performance Data (TN 170)
- Fluorescein Performance Data (TN 179)
Fluorescence Assay Protocols:
RNA
- DeNovix RNA Assay Standard Protocol (TN 199)
- DeNovix RNA Assay Detailed Protocol (TN 198)
- DeNovix RNA Assay Instructions for Thermo Fisher Qubit™ Fluorometers (TN 201)
dsDNA
- Broad Range dsDNA Assay Standard Protocol (TN 142)
- Broad Range dsDNA Assay Detailed Protocol (TN 143)
- High Sensitivity dsDNA Assay Standard Protocol (TN 144)
- High Sensitivity Assay Detailed Protocol (TN 145)
- Ultra High Sensitivity dsDNA Assay Standard Protocol (TN 146)
- Ultra High Sensitivity dsDNA Assay Detailed Protocol (TN 147)
- DeNovix High Sensitivity dsDNA Assay Protocol for Thermo Fisher Qubit™ 3.0 / 4 Fluorometers (TN 207)
- DeNovix Ultra High Sensitivity dsDNA Assay Protocol for Thermo Fisher Qubit™ 3.0 / 4 Fluorometers (TN 208)
Best Practices & Troubleshooting
- Five Ways to Improve UV-Vis Accuracy (TN 180)
- Spectrophotometry Best Practices (TN 106)
- Microvolume Reproducibility Tips (TN 175)
- Sample Surface Cleaning (TN 110)
- Purity Ratios (TN 130)
- Microvolume Pathlength Verification Protocol (TN 123)
- Cuvette Absorbance Verification Protocol (TN 174)
- Diagnostics App Self Test (TN 131)
- Technical Support Files (TN 177)
- DS-11 Series Troubleshooting Guide (TN 165)
Software Notes:
- EasyApps™ Software Highlights (TN 104)
- DeNovix DS-11, QFX, DS-C 21 CFR Part 11 Compliance Statement (TN 217)
- Data App Highlights (TN 134)
- DS-11 Series Android Email Setup (TN 204)
- Email Setup (TN 205)
- Network Folder Setup (TN 122)
- Network Printer Setup (TN 173)
- Export, Archive, Backup and Restore (TN 124)
- Software Update Instructions (TN 118)
- Baseline Correction (TN 119)
- EasyApps™ Software Malware Protection (TN 116)
- Connecting to eduroam (TN 225)
This product is provided under an intellectual property license from Life Technologies Corporation – for more information visit www.denovix.com/license/
NanoDrop™, Acclaro™ and Qubit™ are registered trademarks of Thermo Fisher Scientific and its subsidiaries and are used for identification and references purposes only. DeNovix, DeNovix products and this website are not endorsed or authorized by or in any way affiliated with Thermo Fisher Scientific.